Bragg Studio

STOE .raw patterns, peaks and CIF phases
notes file: — (browse a folder)
drop .raw / .xy data or .cif files (or folders of CIFs) anywhere on the page

Instrument broadening

reference
background pts find peaks % ° 2θ ° 2θ fit η
Open a reference pattern (standard measured with the same settings), or type U, V, W below.
drag = zoom 2θ · double-click = full range · with ⌒ fit window on: drag across a peak to fit it · untick a peak in the table to leave it out of the Caglioti fit
Reference peaks
use2θ (°)θ (rad)FWHM (°)FWHM² (°²)ηχ²redCaglioti (°)Δ (°)
no reference fits
Caglioti
y = W + V·tan(x) + U·tan²(x)(y = FWHM² in °², x = θ in rad)
What U, V and W are
Caglioti, Paoletti & Ricci (1958) found that the instrument peak width varies with angle as y = W + V·tan(x) + U·tan²(x), with y = FWHM² (in °², 2θ) and x = θ.
W (°²): the width at θ → 0. Set by the size of the source (tube focus) and the slits, as seen from the detector, and by the detector resolution (strip width of a PSD) — the angle-independent part.
V (°²): a cross term, usually small and often negative; it shifts where the width is smallest. It mainly makes the curve bend, so it is strongly correlated with U and W and poorly determined on its own.
U (°²): the part that grows as tan²θ. From the beam divergence and the wavelength spread of the radiation (Δλ/λ, i.e. the monochromator), which give Δ2θ ∝ tanθ; a sample with microstrain also adds to U.
The values only describe this instrument with these slits, step, time and geometry; use a reference measured the same way as your samples.

Pattern

view
0 %
peaks
find peaks
pts (0 = off)
° 2θ
%
° 2θ
show data
background pts fit η instrument βs = √(β² − βi²) edit
CIF
35 %
° 2θ
style
labels
scan time: 2θ
Open or drop STOE .raw files (or two-column .xy), then add CIF files to compare.

Data files

0 %
click ⇥, drag a window across a peak: it is marked on every trace · click one mark = reference · click the other marks (or ⇉ align all) to move those traces onto it or 2θ–
showtracename2θ range (°)point step (°)PSD step (°)s / steppointsλ1 (Å)Δ2θ (°)peaksnotes
no data loaded
Metadataof the highlighted file
click a trace to see its metadata
Peaks
#2θ (°)d (Å)1/d (nm⁻¹)FWHM (°)I netAreaI rel %CIF match
no data
Fit results
tracecentre 2θ (°)d (Å)FWHM (°)height (counts)areaη (Lorentz share)χ²redbackgroundwindow (2θ)profile
zoom: click the plot first to switch on wheel zoom (outlined while on; click outside or Esc to switch off, so the page scrolls normally), or drag left–right to zoom to that 2θ interval (intensity re-fits), double-click = back to the from / to range you typed (or the full range; Reset zoom = full range) · shift+click adds a peak at the nearest maximum, × in the table removes one · click a table row to zoom to that peak · marker colours with CIF phases shown: ■ matched within ± tolerance, ■ not matched

Save

Files are only written when you press a Save button.

Rietveld refinement

data
phases
model
background terms instrument ° peak shape η sample texture along
refine
plot:
phasesystemwt %a (Å)b (Å)c (Å)α (°)β (°)γ (°)V (ų)size L (nm)strain ε (%)texture rscalerefl.
no refinement yet
Whole-pattern fit with the structures of the CIFs kept fixed (atom positions, occupancies and B from the files). Each reflection is a pseudo-Voigt with area S·m|F|²·LP and FWHM H = √(Hi² + (Hsize + Hstrain)²), Hi from the instrument function; Kα1 only unless Kα2 is ticked. Texture: March–Dollase along one direction for all ticked phases (applied to the representative hkl of each reflection group). Not refined: atom positions, occupancies, B, absorption, peak asymmetry, sample displacement. Weighted least squares (weights 1/counts).

Phases from CIF

° 2θ
% I
Add .cif files or whole folders (each folder gets its own box). click a phase to highlight it (preview sticks on the plot), ↑↓ step through, space ticks it to keep it shown, Esc un-highlights. Powder intensities: I ∝ m·|F|²·LP, LP = (1+cos²2θ)/(sin²θ·cosθ) (no monochromator), X-ray form factors of neutral atoms (Waasmaier–Kirfel), Debye–Waller from the CIF B/U (0 if absent), no anomalous dispersion, absorption or preferred orientation. Sticks at λ1 of the active trace.
no CIF loaded
Lines
hklmd calcd × s2θ (°)I %obs peak
click a phase to list its lines

3D structure

view along zone []